| Optical Parameter | |||||
| Model | GL532AQ-S12 | ||||
| Output Wavelength | 532nm | ||||
| Operating Mode | Q-switched | ||||
| Single Pulse Energy | 1~10µJ | ||||
| Longitudinal Mode | Single | ||||
| Pulse Duration | 20ns | ||||
| Peak Power | 50-500W | ||||
| Rep. rate | 1~1000Hz | ||||
| Polarization Ratio | >100:1 | ||||
| Power Stability (over 4 hours) | <5% | ||||
| Beam Divergence, Full Angle | <2mrad | ||||
| Beam Diameter at the Aperture | ~2mm | ||||
| Electrical Parameter | |||||
| Power Supply | ADR-1200 | ||||
| FDA Power Supply | |||||
| Input Voltage | 85~240VAC, 50/60Hz | ||||
| Modulation | None | ||||
| Mechanical Parameter | |||||
| Dimensions of Laser Head | 429 × 159 × 139mm | ||||
| Weight of Laser Head | 10.2Kg | ||||
| Dimensions of Power Supply | 334 × 300 × 123mm | ||||
| Weight of Power Supply | 6.2Kg | ||||
| Reliability | |||||
| Warm Up Time | <10 minutes | ||||
| Cooling | TEC, Forced-air cooled | ||||
| Operating Temperature, Case | 10℃ ~ 35℃ | ||||
| Storage Temperature | -20℃ ~ 60℃ | ||||
| Expected Operation Lifetime | 10000 hours | ||||
| Warranty | 12 months | ||||
| Note | |||||
| » The Laser is designed to operate without heat sink. Do not restrict air circulation around the device; an additional heat sink can be used to maximize the performance and life time of the laser. » All specifications are based on performance at full output power and after the specified warmup period. Output characteristics may change if the laser is run at a different power level. » 2-Year Warranty is available upon request. |
|||||
| Accessories (optional) | |
![]() |
|||||
![]() |